 BV1 - Phase sequence relay
Application Supervision of phase loss, phase sequence and undervoltage in three-phase systems.
Function Relay BV1 measures amplitude and angle of three phase voltages. The angle of the phasors determine the phase sequence. Unbalance and phase loss are detected by the measurement of amplitude and angle. www..com The undervoltage trip setting is 70 % of Un fixed. The underfrequency element trips if the frequency falls below 45 Hz.
Technical data rated voltage Un: frequency range: hysteresis: power consumption: thermal load carrying capacity: returning time: minimum operating time:
110 V, 230 V, 400 V AC 45 - 66 Hz 2% Un 3 VA (4 VA BA1-400) continuously 1,3 x Un 700 ms 700 ms
Fig. 1: Front plate
Output relays: max. breaking capacity ohmic: 250 V AC/120 W DC inductive: 500 V AC/75 W DC rated current: 5A making current (16ms): 20 A System data: regulations: VDE 0435 Teil 303 temperature range at storage and operation: - 25C bis + 70C Mechanical stress: shock: class 1 acc. to DIN IEC 255-21-2 vibration: class 1 acc. to DIN IEC 255-21-1 degree of protection: weight: mounting position: IP 40 at closed front cover approx. 0,5 kg any
The unit BV1 is designed to be fastened onto a DINrail acc. to DIN EN 50022 same as all units of the BASIC LINE. The front plate of the unit is protected with a sealable transparent cover (IP40). Please remove the transparent cover with a screw driver to adjust the relay.
LED LED is used to indicate operation without fault with steady light. At tripping or underfrequency the LED extinguishes.
110
65
Fig. 2: Dimensional drawing of BV1
TB BV1 03.97 E
75
1
Auxiliary voltage supply The unit BV1 needs no separate auxiliary voltage supply. The supply voltage can be formed directly from the measuring quantity.
Unit dead, wrong phase sequence or tripped
Operation without a fault
Fig. 4: Contact positions
www..com
Fig. 3: Connection diagram
Connection terminals The connection up to a maximum of 2 x 2,5 mm cross-section conductors is possible. For this procedure the transparent cover of the unit has to be removed.
Order key: quantity BV1 110 V AC 230 V AC 400 V AC 110 230 400
2
TB BV1 03.97 E
www..com
TB BV1 03.97 E
3
www..com
Woodward SEG GmbH & Co. KG Krefelder Weg 47 D - 47906 Kempen (Germany) Postfach 10 07 55 (P.O.Box) D - 47884 Kempen (Germany) Phone: +49 (0) 21 52 145 1 Internet Homepage http://www.woodward-seg.com Documentation http://doc.seg-pp.com Sales Phone: +49 (0) 21 52 145 635 Telefax: +49 (0) 21 52 145 354 e-mail: kemp.electronics@woodward.com Service Phone: +49 (0) 21 52 145 614 Telefax: +49 (0) 21 52 145 455 e-mail: kemp.pd@woodward.com


▲Up To Search▲   

 
Price & Availability of BV1

All Rights Reserved © IC-ON-LINE 2003 - 2022  

[Add Bookmark] [Contact Us] [Link exchange] [Privacy policy]
Mirror Sites :  [www.datasheet.hk]   [www.maxim4u.com]  [www.ic-on-line.cn] [www.ic-on-line.com] [www.ic-on-line.net] [www.alldatasheet.com.cn] [www.gdcy.com]  [www.gdcy.net]


 . . . . .
  We use cookies to deliver the best possible web experience and assist with our advertising efforts. By continuing to use this site, you consent to the use of cookies. For more information on cookies, please take a look at our Privacy Policy. X